Environment

Light Meter
 



GW 6610
$59.00

 

Click image to enlarge - Digital Light Meter
TES 1335
$165.00


 
 
  • Spectral Sensitivity close to CIE photopic Curve.
     
  • Measuring levels ranging 0 to 400,000 Lux, 0 to 40, 000 fc.
     
  • Relative function.
     
  • Cosine Angular corrected.
     
  • Auto Power Off function.
     
  • CNS 5119 Class II
     
  • Peak Hold function.
     
  • Accurate and Instant response.
     
  • Data Hold function.
     
  • MAX/MIN function.

Click image to enlarge - Datalogging Light Meter (RS-232)
TES 1336A
$295.00
 

  • Spectrum of photo sensor meets C.I.E. Standard Illuminant
     
  • 8000 records datalogging capacity
     
  • Lux/Fc selection
     
  • Data-Hold function
     
  • Standard Illuminant A
     
  • RS-232 interface (software included)
     
  • Measurement of luminous intensity (PC Software)
Specifications JIS C1609-1993 ~ CNS 5119-1998 A
Measuring Range:
20/200/2000/20000 Lux 20, 200/2000/20000, Fc
Luminous intensity (cd): Intensity = illuminance x (length)2, Length { feet (Fc) meter (Lux)
Resolution: 0.01 Lux
Accuracy: ± 3% rdg ± 0.5 digits(Calibrated to standard incandescent lamp, 2856K)
Over range display: “OL”
Record (Datalogging): 8000 Point Data logger
Sensor: Silicon photo diode
Sensor lead length: 150cm (approx.)
Sensor probe: 100(L) x 60(W) x 27(H) mm
Main instrument: 145(L) x 72(W) x 31(H) mm / 235g (approx.)
Power source: One 9V battery
Battery life: 50hrs (approx.)
Operating/Storage Condition:
0°C~40°C (32°F~104°F) below 80% RH
-10°C~60°C (14°F~140°F) below 70% RH
Accessories: Carrying case ~ 9V battery ~ instruction manual ~ Software (under Win 95) ~ RS-232 cable ~ 9 to 25 Pin gender changer
Click image to enlarge - Light Meter
TES 1339
$259.00

  • Dual display, 4 digit LCD reading
     
  • Spectral Sensitivity close to CIE photopic Curve
     
  • Measuring levels ranging 0.01 to 999900 Lux, 0.01 to 99990 fc, autoranging 5 steps
     
  • Accurate and instant response
     
  • Integral illuminance measurement
     
  • Luminous intensity measurement
     
  • Data Hold function
     
  • Data memory and read function
     
  • Reference value setting for relative or percentage deviation measurement
     
  • Ripple measurement for STRAY + LIGHT function
     
  • Time-hold function
     
  • Point - average function
     
  • Auto power off function
     
  • CNS 5119 Class II
Electrosmog Meter
Click image to enlarge - ElectroSmog Meter
TES 92
$255.00


 
  • 50 MHz to 3.5 GHz frequency range
     
  • For isotopic measurement of electromagnetic fields
     
  • Non- directional (isotopic) measurement with three channels measurement probe
     
  • High dynmic range due to three channels
    digital results processing
     
  • Configurable alarm threshold and memory function
     
  • Easy to use
Included accessories: 1 x 9 volts battery, carrying case
Manometer
Click image to enlarge - Digital Manometers
MTP ST-8890
$175.00

  • Simple fittings for hose connection
     
  • Digital display of gauge or differential pressure from 0 to ± 2psi or o to ± 5psi
     
  • Over range and low battery indicator
     
  • It features 11 selectable units of measure
     
  • Auto power off preservec remaining battery life
     
  • MIN/MAX and data hold function
Included accessories: Carrying case, software, instruction manual